MembersPage/WolfTm (2017-10-04 10:07:26)

Granting (by info sent in priv),

Do you have ISP cable (Parport DSUB25 or USB-ISP ?) Will need to follow

http://vems.hu/vt/help/v3/general/bootloader_upgrade.html

If considering bootloader upgrade, (so that internal BOD can be disabled) highly recommended:

PLEASE CHECK THAT v3/10267 has reset chip at the atmega128/pin20 reset, eg

See GenBoard/VerThree/Schematic eg

[v3.8.pdf]


Engine off, ambient sensor temp, I'm getting 2.5 volts out of Pin6 (0-5V output, 1V/233.3C).

Thus getting 580°C instead of 20°C.

Tested Pin7 DVM output (1V/100°C) and getting 0.7 volts (and not 6 volts, roughly corresponding to Pin6 2.5 volts).

EGT sensor is K type yellow-red wires:

  • yellow = green (plus wire) to board GND
  • red = white (minus wire) to the board cathode on corner