Error report: 2012-06-22 01:43:01
Status: New

Report generated: VemsTune (Help menu/Error reporting by one-click)
log for audi s4 aan
ignition coils tested ok
measurement sensor
ohm between 44/30 ,728kohm
ohm between 45/30 2,69kohm
aan pin 10 0,4ohm
aan pin 19 1,3ohm
aan pin 24 1,2ohm
aan sensor pin 30 4,7mohm
aan sensor triger 48 open
measurement triger 49/48 1kohm
measurement triger 47/48 1kohm

fault
no start no spark tested no rpm signal. do not know which firmware has been used

user name: morne
Note: You can share the link with your friends or keep it secret.
Show/Hide report details
Comments 
admin 2012-06-25 15:06:54
This still does NOT contain .vemslog !
But at least it has the first "no RPM" (actually probably means RPM=0)
Info copied to
http://www.vems.hu/wiki/index.php?page=MembersPage%2FMorneAudi (with link here).
Marcell
Attachments
No attachments.