Still having trouble with round (manufactured 2021-08) firmware 0.7.51
REPRODUCED ISSUE in lab. On good track now. Thanks for the patience
config.display_mode[0]=80 THIS CONFIG IS WRONG, >=80 (upper nibble >= 8) is for AIM function, but AIM it does NOT receive.
- Workaround: Edit file, like:
- config.display_mode[0]=00 instead of 80 (to display Lambda and EGT: recommended)
- config.display_mode[4]=50 instead of D0 (to display AFR, not recommended)
- and upload config. We're examining why VT does not make it more obvious that display is set to AIM.... (TODO: how to configure with VT for non-AIM ?)
The gauge is happy that the sensor is working and showing correct lambda in VemsTune.
- "display is slot 0 and max is 0 it's still showing -FU (problem!)
- Display Peak values="actual values" are selected, right ?
- Correct
- Display Peak values="actual values" are selected, right ?
It can show other things in the top row, but AFR or Lambda just shows "-FU" (indicating possibly Display Peak value="peak value" selected instead of "actual value", or target not reached problem, are the wires safe and sound ?).
- Wires must be safe and sound I?ve already used the 0-5v output to tune an engine with this and the 0-5v responds exactly as expected, x% more fuel in ecu = X% more richer in vemstune and on the analog out
Can you do Tools/Firmware verify 0.7.51 ? (just in case)
- uploading any other firmware version is not currently supported (this has full functionality, and no other fw relased for this device).
Please investigate and respond to report crvGcr
- we upload a config that shows correct lambda/O2
- your config (extracting from report)
- I?ll upload the latest config to the report.
- All configs ever uploaded to report
- I?ll upload the latest config to the report.