MembersPage/VacsiImre (2017-01-23 13:10:21)

v3.3_u010262 mainboard home-assembled

Second Wbo2 needed some components (even for a mainboard, just request in order comment and gets installed for no extra charge).

Installed Resistors:

- R28 -100k

- R29 -510ohm

- R137 -10k

- R140 -10k

and Q14 FET

Pin out:

- EC18/1 WBO2_2 Nerst

- EC18/7 WBO2_1-2 Pump-

- EC18/8 WBO2_2 Pump+

- EC18/9 WBO2_1 Pump+

- EC18/13 WBO2_1 Nerst

- EC18/17 WBO2_2 Heater

- EC18/18 WBO2_1 Heater

Procedure to calibrate or recalibrate your WBO2 controller built-in to VEMS V3

Verify Pump-

My board measure 4.05V

Measure Pump+ and Adjust Pump-pw-zero

My board measure 0.8 mV

Verify Heater

LED lighting.

Nernst-DC target

Adjustable 450mV

config and log

Assuming you could free-air calibrate LSU4 sensors for both channels (after 2nd WBO2 components completed; and enabling 2nd WBO2 in config).

Care to write measured Rcal (between Rcal which is not a real sensor-pin and pump+) and calibration value ?

http://www.vems.hu/filethingie.php?action=list&subdir=VacsiImre


Q Could you take a vemslog of 2nd wideband calibration sequence (from sensor cold), with the following options:

After receiving your logfile i will review and make suggestions on how to proceed.

Best regards, Dave

________________________________________________________________

Hi Dave!

A vemslog is upload. Vemsfile area- VacsiImre.

Thanks

Imre


Hi!

v3.3_u08562 mainboard home-assembled

fw 1.2.37.

Szükségem van az AIM adatokra, a 125-ös csatorna adataira is, pontosan a warning lamp bitje érdekel. A régebbi fw tartalmazta ezen csatornát, viszont a többi csatorna hiányos volt. Most ami érdekel megvan, csak ez az 1 adat kell még.

I need the AIM data, the data on channel 125 as well. Exactly the warning lamp bit interested. The older fw contained in this channel, but the other channels was incomplete. Now that interests you have, but this data has to be one.

Thanks.

Imre