MembersPage/PappIstvan (2010-07-16 21:09:25)

Primary Trigger

terheletlen feszültség: 2,85 V

1Kohm-os ellenállással 284 mV

a polaritás megfeleli

http://data.hu/get/2745756/v3.3_n003213-2010.07.10-19.02.09_papp.vemscfg.html

We concluded that p259 was likely damaged during the install

Output collision ! Change fuel pump output (now an injector channel is selected for it) to NOT collide with an injector !!! Use injgroup 4..7 (NOT 0..3 = A..D)


the p59 repaired sucessfully. but we dont have trigger signs.

http://data.hu/get/2763275/v3.3_n003213-2010-07-16.21.17.24.triggerlog.html

anybody idea?

Trigger looks like 60-2 but REVERSED VR polarity! - there should be one long tooth *3 than appr previous time.

[full log]

Your VR trigger is apparently reversed ! (HU: forditott polaritásnak látszik. Azt mondtátok, megcsináltátok a multiméteres "csavarhúzó"-tesztet. Vagy mégsem ?).


We checked the polarity and it was correct but we will try to reverse the polararity tomorrow, and upload the new config file.

Thanks for your patients.