MembersPage/Norbitron/ETC (2017-06-13 13:29:16)

2pc ECU has been ordered in the following option:

2 x ECU VEMS V3

- LCD connection: yes

- Knock input channels: 0

- ignition driver: 4

- Hi-side PFET outputs: 0

- Flyback: HighZ-only 30V flyback

- ETC BridgeOutput_Interface: 1

- EGT input: 2

- 1-wire interface: no

- mounting-style: flanged case

- MAP connection: 400kPa (5/3mm pneumatic)

- primary_trigger: HALL

- secondary_trigger: HALL

- Service: ASAP

- Special requests: no

- withSDcard: no

ECU numbers: 14116 and 14115

And ordered an ETC bridge controller with defaul settings

I have same problem with both ECU. Followed the instructions from help menu step by step when it calibrated.

TPS1-2,PPS1-2 inputs calibrated

TPS% without ETC controller is on 5%

At first time when i connected the ETC motor to the bridge(ETC DC was 0%) the TPS went up to 100%. I Tried on ETC DC=100% the TPS=0% . Ok i tought i have to swap the ETC motor pins. I did it but when i raise the ETC DC From 0% to 100% The TB is closing not opening.

My measurements:

VBatt=12.19V

ETC DC=0% (in Econoseal10 connector)Between Pin1 and GND = 0V, BTw Pin1 and Pin2= -12.14V, Btw Pin2 to GND=12.15V

ETC DC=100% Btw Pin1 to GND = 12.19V, Btw Pin1 to pin2=0.11V, Btw Pin2 to GND = 12.08V

Maybe a wrong FET inside the Bridge because the Pin 2 voltage doesn't change?