MembersPage/NanassyPeter/Status (2005-12-24 04:11:48)

Looks like I need a different matfactor / thermfactor (and maybe airdensfactor too)!

LCD displays -24..-26C air temp instead of -6 .. -8C

The full vems.hex must be uploaded, but only the first part will be changed, 0x0100..03FF

Do you maybe have new tables ready ?

yes i have new tables ready,but i will have to change the whole thing tough,i realised that for proper everyday use i need more VE resolution on the lowboost section,so i have to change the brake points for the VE table.

any update on these??:

-MAT rescale

-MAT ignition retard

-custom oil temp/pressure gauge with V3.3 and LCD

-5 coil tach?


MAT - airdenfactor

At 0 Celsius the displayed MAT is -16 Celsius. Therefore the ECM enriches appr. 6% (as it should, according to the gas-law), this must be fixed.

We really do not want to hack by raping the gas-law. Instead we fix it the proper way, with proper matfactor and airdenfactor tables.

Working on suitable tables, so the relevant section in the vems.hex can easily be changed (with notepad or any simple editor, or patch, or small program).

When

This is huge difference (255-201)/(255-231)= appr. 5/2 (*2252 Ohm), so likely your sensor has quite greater resistance than 2252 Ohm.

In this case only this 0C datapoint is just not enough to get good calibration result (it's possible to make it show good at 0C, but we don't want to hide bad readings at higher temp!)

Can you provide another measured data-point ?

Either resistance or temp-reading at known temp.