MembersPage/NanassyPeter/CustomerRoundWideBand (2007-02-19 09:20:12)

Suspection was right,the EGT sensor was burned.Replaced with the uprated version.Now my customer needs a special EGT and Lambda output.I need the support for the URGENTURGENT.The race season just begins....

The spec he needs:

volt lambda

0,00 0,68

0,50 0,75

1,00 0,82

1,50 0,95

2,00 0,95

2,50 1,02

3,00 1,09

3,50 1,16

4,00 1,22

4,50 1,29

5,00 1,36

egt:

volt egt

0,00 0

0,50 150

1,00 300

1,50 450

2,00 600

2,50 750

3,00 900

3,50 1050

4,00 1200

4,50 1350

5,00 1500

Thanks,

Peter


A customer reported a bad EGT sensing problem.

EGT shows 3-4Celsius all the time.

Possible solutions?

>It worked previously for about 6 months,nothing changed since that.

//pnanassy

MembersPage/PhatBob Has he inspected the end of the sensor? They ionise to destruction in the exhaust stream. If he had more than the top 3mm exposed then it will have burn off in six months