MembersPage/NanassyPeter/CloneInstall/Wiring (2006-02-28 00:02:34)

For this im using PhatBobs beautifull Install User guide,

MembersPage/PhatBob/UserGuide

which is currently not covers how to wire up 5 COP's.

Because of the very high output of this turbocharged engine we will use 2 individual fuel line with 2 fuel pump,and of course 2 fuel pump relays.

Q: Can i run this two relay from the dedicated fuel pump relay output of the vems ECU,namely from the

EC36-pin15?

A: Yes, switching the both relays parallel is no problem at al an should work fine as long as the combined current from the relays does not exceed 250mA (unlikely)

This way

Connecting2FuelPump.PNG

I wired the injectors like this:

Q

What do you think,is this correct?What will the second group do when they are swithed off with removed FUSE,but they are still wired together via injector common flyback?

ConnectingInjectors10.PNG