For this im using PhatBobs beautifull Install User guide,
which is currently not covers how to wire up 5 COP's.
Because of the very high output of this turbocharged engine we will use 2 individual fuel line with 2 fuel pump,and of course 2 fuel pump relays.
Q: Can i run this two relay from the dedicated fuel pump relay output of the vems ECU,namely from the
EC36-pin15?
A: Yes, switching the both relays parallel is no problem at al an should work fine as long as the combined current from the relays does not exceed 250mA (unlikely)
This way