We're investigating an engine setup
First we would want to confirm that trigger is 48+1 (unmodified LS1 with 24 tooth on crank without missing tooth), as on:
Triggerlog
All logs up till now have been done with "trigger type = coil type" and "divbyN = 2".
- Both pri and sec trig edge are "Falling". Regular "coil type" with "LS1 forgiving" enabled for sec trig.
- Pri trig is (must be) falling edge to get evenly spaced teeth.
Triggerlogs and vemslog with engine running and having issues. Examples of cranking and idle, with "LS1 forgiving" both dis- and enabled.
- http://www.vems.hu/files/MembersPage/MattiasSandgren/LS1/
- I will report back with "special trigger type = normal" instead of "divbyN", to visually show you all the 24 (48) teeth.
Note about triggerlog capture below: auditrigger divby2 so the missing tooth might be "optical illusion" :