Audi RS2: Long Block 2.7 liters, Motronic VEMS, 7.5 to 1 Comp, Precision 6265, 10 bosch injectors 550cc @4bar. 034 DIS high output coils, 60-2 crank sensor.

MembersPage/LoloQuatro audi ADU idle too high at 2000rpm, IAC badly controlled

MembersPage/LoloQuatro audi ADU no craking when cold, ether needed link to the log is now available

LoloQuattro 07/02/12

Thanks for your request for additional details, I have inserted some clarification

03/02/2012

LoloQuattro

Now the hot start and idle is solved, I still have a problem to start.

Here are the parameters for cranking.

Priming, crancking setup

Primepulse 0.0ms

Hot start primep temp scaling 20%

Cranking threshold 399rpm

Crank Ignition advance 9.0°

Crank VE 60%

Afterstart setting (-40°c) 12 cycles

Afterstart Warm Time (77c) 0 cycles

% of Warmup Enrichment at highest RPM 66%

% of Warmup Enrichment at 100kpa 90%

My crancking enrichissment curve is:

-20°c 300%

0°c 200%

30°c 150%

70°c 100%

Afterstart Enrichment curve

-20°c 275%

0°c 181%

30°c 138%

20°c 100%

Warmup Enrichment Curve

-40°c 140%

-30°c 135%

-20°c 130%

-10°c 127%

0°c 124%

10°C 120%

30°c 110%

40°c 107%

60°c 100%

69°c 100%

IAC duty at crancking

-40°C 85%

77°C 42%

IAC reference curve just some points

-40°c 60%

...

0°C 30%

...

69°C 23%

Any suggestion ?

What kind of injectors and fuel do you use?

LoloQuattro 07/02/12

Bosch green 440cc

- assuming on pump gas (?)

How starting is bad? Is it cranking forever, or firing some strokes but cannot rev up, or revs and dies? ...

LoloQuattro 07/02/12

It did not start at all, it is crancking forever, I must inject Ether to have a start and then it is OK.

Once warm if I stop, it can restart it is OK.

You should give more details, preferrably your full vemslog/vemscfg files.

LoloQuattro 09/02/12

Here is the log, I am obliger to put ether in the intake and press full trottle to start

http://www.vems.hu/files/LoloQuattrobadcoldlogfile/