Q: I do not seem to be able to get the PWM for the idle to change with RPM
I played with all the seting and I can change how much it is open by changing Max steps to extend. but it seem to stick where ever I set that to
the speed/PWM seem to need to be 0 or 1 if I set the number larger that valve pops open close very fast(likly to damage)
the rest of the setting seem to have no affect. except for TPS threshold that tells it when to turn on.
if I set the Max steps so the valve is open 1/2 and change the RPM up/dowm past ether the cold or the hot idle seting the valve dose not move at all.
I also tested with ignition basted idle on and off
I also tested with Asymmettic PID on and off
this is with 1.0.45 FW
Some notes about the valve. This is a motronic valve
- if there is no power at all going to it it looks to have a limp mode where it is part open.
- as you start to give it voltage it will close
- are you sure about this ? it means the valve is non monotonous actuator, which is strange.
as you add voltage the window will move and start to close when the window is centered the valve is 100% closed. Then as the voltage in increased the window will open on the otherside and can keep on going untill 100% open.
- then any more voltage it will start to open again. The more voltage the more open.
min PWM and a max PWM setting are easy, since you can adjust the ("stepper", same as PWM) reference positions in function of CLT. Sufficiently low (05 ?) iac_integral_limit_dec helps you to limit PWM to go much lower than you like (useful anyway).