Primary trigger: 60-2 w/ VR sensor.

Secondary trigger: Single tooth w/ Hall sensor.

Firing order is 1-2-5-3-4.

MembersPage/RonnieH has set up VEMS on a very similar motor also with seq. COP. Should be able to lift his trigger settings assuming he left the stock sensors in place.

(Incomplete)

Field name (var name) Field value [decimal] (Var value [hex])
Primary Trigger (primary_trigger) 1 (0x01)
Edge Rising
Type Multitooth
Filtering...Bit7 Disable
TDC after the trigger () 60.0
Number of teeth on wheel (tooth_wheel) 58 (0x3A)
Trigger tooth (trigger tooth) 5
Next trigger tooth (another_trigger_tooth) 24 (0x18) (from GenBoard/UnderDevelopment/FirmWare/TriggerRelated )
Crank min. period ()