MembersPage/JyrkiK (2007-03-25 10:05:42)

I have Genboard 3.3 (1.0.53) installed on my car, and i have some problems with those .bat files installed on my computer.

When connected to car, download-config.bat works fine, but when running generate-config.bat it doesn´t work right.

Tables.mtt is generated ok, but config.mtt have ERROR text first on every line.

At the end it says Config.mtt generated with 255 errors and 0 warnings.???

Tried with new .exe file , but still the same...

at what com-port is your laptop communicating with genboard?

when this is another com-port as the bat-file uses then you have to edit the batfile with a texteditor to adjust its com-port. Tim

Edit your config.txt with Programmers notepad, Do not use windows notepad. There is note about this in here somewhere on wiki.

I had similar problems because windows notepad somehow mixed up config.txt and give multiple errors when trying to generate config.

Then finally editing with Programmers notepad there was many lines containig text from multiple lines.

I separated texts to their own lines, saved and everything worked OK!

25.03.07

Doesn´t work either....

I´ve got false reading in clt and mat at lower temperatures, when temp is like +15c outside,lcd shows then +22 or +23 celsius.

I´ve measured those sensors, and there´s my list:

MAT

1 6140

10 4080

20 2720

30 1840

40 1279

46,5 1000

50 882

60 630

70 459

80 343

90 263

CLT

-

1 5770

10 3960

20 2630

30 1760

40 1208

50 856

60 607

70 449

80 331

90 270

I´ve read that easytherm thing but imo it´s bit messy..

So could somebody tell me what to do to get those readings right?