Remember to publish battery calibration so we know AREF (287 or 256) for proper temperature table selection (that also precise at very low temp)
I downloaded EasyTherm and filled in my three reference points:
CLT:
- -2 6500
- 20 2500
- 160 50
IAT:
- 0 5000
- 20 2200
- 100 300
See EasyTherm cltfactor_2400_287.hex and airXfactor_2252_287.hex seems close (for above data) that can be applied to vems.hex with hexpatch.exe (that upload the patched vems.hex and there you go!).
No need to change MegaTune.