MembersPage/GrmRacer/WbCal (2006-01-18 08:15:29)

This page is intended to document the actual method to WBo2 calibration for Vems 3.x process in one location in an easy to understand format for use with a windows box and MegaTune

Instructions for calibrating WBO2

These instructions are for bench calibrating your WBO2

There are two steps.


Calibrating pump_zero

''This portion is a non-issue if you purchased a v3.3 and got an email with

the pump_zero value in the email from the webshop. ''

You will be changing this value

[ Highlighted box in MegaTune ]

Turn on VEMS unit.

Leave trigger off ( no rotation of crank or no stimulation of box)

Leave WBO2 off

This is a fresh boot only power applied.

hook up a Voltmeter between pins 5 & 6

[see photo]

of the WBO2 connector

[see photo]

from the EC-18[photo]

and measure the voltage.

[Overall cartoon]

This voltage is "as close to zero as possible"

output that has 256 values over 5 volts. So each point adjusts the voltage

19mV == 0.019 Volts.

positive and negative leads for your VoltMeter. Changing the value Up one point

will move the pump_pwm_zero up 19mV, otherwise it will drop 19mV.

you have to "burn to eeprom" and reboot the VEMS box to make the changes take

effect. You have to do this each time to see a change.


Free Air Calibration

Now that the pump_pwm_zero has been set you are ready to do the

free air calibration. You will be changing this value

[ Highlighted box in MegaTune ]

are for air fuel ratio NOT Free oxygen.

get up and running

mde02 can also turn it on.

Manmlp07 shows output

changes for pump cal dont take effect until you reboot v3.x

The current flows thru a 510 ohm resistor and a 10kohm resistor.

measuring the voltage is a valid test. The question is what is the

allowed tolerance.

5V / 256 = 0.019 V / bit

+/-20mV is minimum

170 changed to 20.0 (3.824)

175 changed to 20.3 (3.843)

180 changed to 20.5 (3.863)

185 changed to 20.9 (3.882)

186 changed to 21.0 (3.882)

190 changed to 21.2 (3.902)

minicom in r30

Manmlp07mllbyebye

Man moves to comm mode

mlp07 changes to WBO2 setting

mll displays content

byebye ends terminal mode and returns to megatune\n

5V / 256 = 0.019 V / bit
+/-20mV is minimum
170 changed to 20.0 (3.824)
175 changed to 20.3 (3.843)
180 changed to 20.5 (3.863)
190 changed to 21.2 (3.902)
185 changed to 20.9 (3.882)
186 changed to 21.0 (3.882)  

I guess we should recommend a starting value (RCal=115 Ohm or so), and get the user read the O2% in free air. We make a table which the user can look up in 1 step => voila: WBO2 is calibrated.