Hello. We are working on a Supra MK3 6 cylindre inline. We are driving 3 double coils on pin 33, 34 & 36 whit succes. We have wired 3 sets of injectors ( as OEM ) and are driving them whit INJ A, B, C, & D.
Our problem is that when we idle we are only getting 0.9ms opening time at lambda 1, and therefore will the injectors not atomize good good enough. Is there a way we can get higher opening time? Our idle target is lambda 1.
Our H2 is:
0 = 1
1 = 2
2 = 4
Our req fuel is 5ms.
Any ideas. Here is the MSQ File:
http://www.vems.hu/files/MembersPage/Daniel/Supra%20MA70%207MGTE%20GT35R/Supra.msq
Thanks for your time!
As I understand now your injectors fires twice per cycle. I suggest rewire on six INJ outputs and run it once per 720deg. MembersPage/GintsK