1993 Audi USA B4 90 quattro with 4.2 ABZ V8. Car in Colorado.
Got new ECU V3.8.
ALL wiring, grounds, fuses, etc. double and triple checked, insulated, etc. etc.
Trying to run on full sequential COP for first time. Has always been dual mode.
Engine was running smooth on old ECU. Current upgrades do NOT run. Engine won't rumble on starting fluid (fuel is OFF) but pings and coughs.
Trigger log seems good. Suspect fire order? But how?