IssueReports/VemsTune (2010-11-15 19:52:02)

In case of bug reports please do not forget to write

  • I have the same problem(0.9.85)

An installer says: "When a customer has problems I like to be able to send finished mtt files to him, these can then be sent with command line tools or if he has communication problems I help him with bray over the phone"

Finished files make a lot of sense. It was planned that one would send project file, where the RIGHT firmware and/or config can be uploaded with 1..2 clicks (not lost in menu-s).

Note that the vemstune over the network will be very useful in many cases, but dealers still need a way to prepare project / vemscfg files (in a documented way!) that can be uploaded extremely quickly (without using menu-s) by a computer-illiterate child supported over the phone.


Gauges


Firmware Version

How do I get 1.0.79 to work with the current version VemsTune?


VT version 2010-07-08 + 1.1.78 FW:


VT version 2010-07-08 + 1.1.74 FW

normal_vetune.JPG

VT version 2010-07-16


VT version 2010-07-19

Analyze Trigger-Log consumed way too much processor and did not work on slower-CPU notebooks. From 2010-08-06, now it doesn't use excessive CPU and useful even with Nx100 MHz slow hosts too.

VT version 2010-07-19

fw:1.1.70, when i wanted to erase the sd card (tools/sd card log/erase) vt crashed. After erasing the sd with on older VT, start, stop, extended overview functions are work.


VT version 2010-08-19

It is impossible to remap MAT/TPS enrichment table with MAT values below zero. X axis negative values are incrasing every time I reopen MAT/TPS table. (fw 1.1.75, 1.1.80, 1.1.81)


VT version 2010-10-01

When attempting to establish the initial config for config B, the change will not write correctly, resulting in strange behavior. It seems that writing the config.txt manually and running ManmcS1 seems to fix the problem and afterward everything seems to work correctly. From a conversation with Marcel on IRC:

(5:47:32 PM) a4kquattr: the other ecus I've tuned that have this sort of feature, the "null" second config is to be expected. usually you save out the config file (eg vemscfg), do the conf switch, then open the saved config to make both halves equal.

(5:49:37 PM) cell_: yes, that works most of the time. But IIRC in rare cases when condswitch value before initialized in 2nd table is unfortunate, it won't. That's what they found recently, and dunno the state of the cure


VT 10-15-2010

Significant memory problem,

VT is taking up 600mb+ of memory when a log file is loaded.

VT takes about 42mb when live connected.


VT 2010-10-19

Still has a memory problem

loaded a 1mb vemslog file, vemstune consumes 324mb and crashes very easily when roaming through the log.

- Further information :

If one log is loaded then excessive memory is used up, if another log is opened without turning the program off then even more memory is used, 1.8GB now with only two 1mb logs opened and them reviewed just a little bit.

Every time the cursor in the log is moved almost 40mb more memory is consumed.

Roaming is moving the cursor to another point in the log

-I'm pretty sure that you are using the 2010-10-15 release please double check the version in Help/About menu!


VT 2010-11-15 (nightly)