Instructions for 60-2 crankwheel with 1-pulse cam

Camsync is necessary for

Cam-sync has been used with coil-type (primary-)trigger (which means ncyl evenly spaced pulses per camrot) for a long time. However, many likes to use camsync with 60-2 crankwheel, which is now possible.

AdvancedIgnition will finally take over (development branch), that also supports odd-fire-6.


notes for users

Implemented with 60-2 since 1.0.24 (experimental! not a real release yet! use at your own risk!)


developer notes

The trick is when the missing tooth is detected.

That way tooth_cnt count up to almost 120.


Design decisions

Might be done in

might be configured in