Things below are mostly outside the scope of ECU - they are controlled by simple sensors (widely available in the AC industry) and relays.


Air Conditioning clutch output:

Clutch active when signal +12V. appr 450mA (26 Ohm)


Air Conditioning clutch output activation rules


Main fan activation rule

Note that the main fan usually draws 30..40A - almost always a relay is used and a 50A fuse.

The main fan is the 2nd biggest current eater (after the starter motor).


Input signals

AC system pressure signal

Naturally, a single pressure sensor can be used instead of the above range switches (eg. an MPX700A).

Other signals


Misc stuff

These might surprise the unaware, when debugging an AC system:


Some systems are certainly different to some degree.

Automatic AC systems have somewhat more parts, eg.


Vasilis' suggestion

i think i have a solution for a very stable idle control for the audi

engines that can have a good solution for the A/C function as well,

and can make it work with the IAC valve+diode

on my logs and current version of 1.1.27 i have noticed that when the

A/C comes on, the IAC PW increases and so the idle drops. Same thing

happens when the fan kicks in or more electrics come on at the same

time. If you have good PID control then the bounce is minimal and you

can get away with it.

BUT if you were to ask the developers to input this kind of dialog for

a future firmware version under idle settings,i think you will have

the best aftermarket ECU for idle control with simple steps!

Here is what is needed:

Under idle settings, put a dialog, IF A/C turns ON, then decreace Idle

PW by X number.

If you cannot control the AC function through VEMS, ( i mean when it

comes ON or OFF) then you can actually do this by using battery

voltage:

SO if Vbatt = 13.00 then IAC PW decrease by X number

so you can make a simple table of 5 values (i dont think more are

needed) so that the IAC PW can change depending on Vbatt.

This can work in combination to the IAC PW/ CLT.

So for example when CLT=80 and IAC PW=20 if vBatt=14.00

BUT if CLT=80 and vBatt = 13.40 (just when the fan kicks in) then IAC

PW=18 etc.

That way you can possibly eliminate the problem with idle drop AND use the IAC succesfully.

We '''actually do that since 1.1.4x : apply higher IAC PWM duty with lower VBATT voltage. (It's done automatically, unconfigurable atm).