400kPa Voltage / kPa table

0.2 -> 4.8V for 20kPa absolute -> max pressure

LINEAR => basic math => any intermediate values, or table with any number of points. On paper, or with formula in xls, or Octave / matlab :\n

V=[0 : 0.2: 5]
# For the 400kPa sensor this means 20-400 kPa :
kPa=(V-0.2)*(380/4.6)+20
[V', kPa']
     0.00000     3.47826   out of precise range
     0.20000    20.00000  min REFERENCE point
     0.40000    36.52174
     0.60000    53.04348
     0.80000    69.56522
     1.00000    86.08696
     1.20000   102.60870
     1.40000   119.13043
     1.60000   135.65217
     1.80000   152.17391
     2.00000   168.69565
     2.20000   185.21739
     2.40000   201.73913
     2.60000   218.26087
     2.80000   234.78261
     3.00000   251.30435
     3.20000   267.82609
     3.40000   284.34783
     3.60000   300.86957
     3.80000   317.39130
     4.00000   333.91304
     4.20000   350.43478
     4.40000   366.95652
     4.60000   383.47826
     4.80000   400.00000  max REFERENCE point
     5.00000   416.52174


MAP-board 1.0

Important: the pinout of internal sensor can be found on GenBoard/Manual/Wiring/ManifoldAbsolutePressure

MAPdongles_and_bare_s.jpg

Pin1 (of the black SSC-male connector) is the leftmost on the above picture (you can verify the pin numbers printed on the female).

The packaged sensor is casted with epoxy, very durable, you can step on it or melt the external softer black part without damage to the internals.

The 400kPa version is recommended for > 130kPa (1.3bar, 18psi) boost. On the 12V, 400kPa version, there are some simple extras onboard, like

You can tell the different versions by the number of actually present SSC pins (3/4/5).


Pinout of the 12V, 400kPa version - most popular

Note that populated this way, the supply has a wide range, and the 5V is output, not input. Applying 5V to the 5V output is not supported, it might damage the unit. Use the 5V version if you want to power something from 5V (max 50mA). This version has (all) 5 male pins (none missing).

SSC pin recommended color signal range note
1 white MAP output 0.2 .. 4.8V 20..400kPa
2 brown GND 0V  
3 red 5V out 5V max 80mA. Useful for HALL, TPS, etc...
4 blue temp out 0.5 .. 4.5V NTC, similar U(T) as CLT
5 grey +12V in 6.3 .. 16V  

Pinout of the 5V, 400kPa version

SSC pin recommended color signal range note
1 white MAP output 0.2 .. 4.8V 20..400kPa
2 brown GND 0V  
3 red 5V in 5V max 10mA
4 blue temp out 0.5 .. 4.5V NTC, similar U(T) as CLT

This version has 4 male pins (out of 5: 1 missing). The first 3 pin is compatible with the MPX4250AP pinout.


Pinout of the 5V, 250 kPa version

SSC pin recommended color signal range note
1 white MAP output 0.2 .. 4.8V 20..250kPa
2 brown GND 0V  
3 red 5V in 5V max 10mA

This version has 3 male pins (out of 5: 2 missing). Note that there is no temperature output in this version.


See also