GenBoard/Manual/Wiring/ManifoldAbsolutePressure (2006-03-16 04:43:08)

MAP-board 1.0

Important: the pinout of packaged external sensor

MAPdongles_and_bare_s.jpg

can be found on GenBoard/Manual/Wiring/ManifoldAbsolutePressureExternal

The "bare" version is ment to be mounted in the ECM case:

The adapter is designed to carry the 400kPa MPXH6400 sensor. Motorola packages this nice sensor in SMD only, so a PCB was necessary for a clean install. Output is compatible with the more common MPX4250AP sensor, but features 400kPa range instead of 250kPa. Recommended for > 130kPa (1.3bar, 18psi) boost.

there are some simple extras onboard, like


Mounting the 5V "bare" version

The "bare"-board is ment to be mounted vertically in the Alubos case, perpendicular to v3.x

MAP_400kPa_mounting_m.jpg

The image is taken before hotmelt is applied (at the connection of the boards and the sensor nipple).

When mounting onboard GenBoard/VerThree, for mechanical stiffness:


Internal version is only practical with 5V supply, to match the supply provided by the GenBoard/VerThree header. It's possible to order the "bare" board with 12V supply, for other applications, if you really know what you are doing.

Pinout of the 5V version

pin nr. signal range note
1 MAP output 0 .. 4.8V 20..400kPa
2 GND 0V  
3 5V in 5V max 10mA
4 temp out 0.5 .. 4.5V NTC, similar U(T) as CLT
5 GND internal 0V  
6 not connected -  

The first 3 pin is compatible with the MPX4250AP pinout.


Pinout of the 12V supply version

'''Important: while the 12V supply is a nice option for the external GenBoard/Manual/Wiring/ManifoldAbsolutePressureExternal, for the internal the 5V is what you likely need when used inside the v3.x case. The 12V is only for special applications, not suitable for direct mounting on GenBoard/VerThree.

Note that populated this way, the supply has a wide range, and the 5V is output, not input. Applying 5V to the 5V output is not supported, it might damage the unit.

pin nr. signal range note
1 MAP output 0 .. 4.8V 20..400kPa
2 GND 0V  
3 5V out 5V max 80mA. Useful for HALL, TPS, etc...
4 temp out 0.5 .. 4.5V NTC, similar U(T) as CLT
5 GND internal 0V  
6 +12V in 6.3 .. 16V  

See also