GenBoard/Manual/WideBandDualWboHardware (2020-04-15 15:52:06)

If a certain VEMS ECU is ordered with "Dual WBO2 requested" (option, or order comment), this should NOT be needed.

Provided for reference (during some debug/diagnostics, or if converting an old device ordered without Dual WBO2).


2nd WBO2 hardware channel on v3.x. Verification of this doc is in progress, use GenBoard/VerThree/Schematic for now.

dual_wbo2_check.png

Problem: When I bench test/calibrate:

I notice the second heater stops heating when the pump- to nernst goes positive (when it normally goes to 450mV).

Thoughts on this? I'm using 2 resistors ( pump- 100 Ohm nernst 100 Ohm pump+), as outlined in the Hardware Test page.

Calibration data with 2 100 ohm and 2 95 ohm (didn't have through hole 100ohm left)

I'll document the process similar to GenBoard/Manual/WideBandHardwareTest once I understand what I'm missing with this dual wideband testing.

First we review your actual configuration

  • Hi, as I understand you are modifying existing vems board, have you guys removed solderblobs for wheelspeed 1 and knock 1, I remember I had some bad experience when was trying to make second wb working, those were the problem. Valdas. And btw, you seem to be missing c26 in your list of modifications.
  • C26 didn't help the problem
  • Already took care of the solderblobs for knock/wheelspeed and the one for second wbo2. I need to add that SJ18 (bottom side) to my picture.

I usually use this document: http://www.vems.hu/wiki/index.php?page=GenBoard%2FManual%2FWBSensorControllerCompleting

PS, captcha stuff seems to be throwing error on chrome browser.