GenBoard/Manual/InputTriggerHardWare/AudiTriggerHardware (2022-01-26 10:31:47)

VEMS V3.9 AAN is by default

Conversion to VR, HALL if ever needed for a non-factory setup.

InputTrigger/AudiTrigger with camHALL inverter, which means:

  • convert to HALL by: disabling the 2nd LM1815 by removing the sectrig LM1815 (U110 ?) output SJ7 solder-blob on the bottom (that connects LM1815pin12 output to the microcontroller input pin). This blob is on the bottom, under the FETs. output solderblob at the bottom side under the FETS so that HALL signal will reach the processor and work (VR will be ineffective as a result).

IMG_0013.jpg

If you need to check, basically same HW since v3.6 (eg. v3.8 or v3.8b), see "See also" below


For secondary trigger HALL (or sectrig unused)

v3.6_sec_trigger_1_m.jpg


See also: