Standard genboard ignition outputs
These show you ignition (i259) channel assignments to EC36-xx pins:
Depending on webshop options you've chosen during ordering, some of the 8 are high power outputs, the rest are logic-level.
It is easy to measure which are logic-level outputs, because logic-level output pulls toward GND5 when inactive. Measure DC voltage on output, with your DVM (20V mode), with +12V (or +5V) being the base.
If DVM shows -12V, than either
- output is logic-level output in inactive state or
- output is power output but active state
- to prevent this: disable all digital outputs in config, and do NOT apply trigger-signal
New standard - power and logic level ignition outputs since 2006-12
IGBTs | Nickname | power outputs | Logic level outputs |
0 | 0 | - | 0,1,2,3,4,5,6,7 |
2 | 2+6 | 2,3 | 0,1,4,5,6,7 |
4 | 4+4 | 2,3,6,7 | 0,1,4,5 |
6 | 6+2 | 0,1,2,3,6,7 | 4,5 |
8 | 8 | 0,1,2,3,4,5,6,7 | - |
Option 0 All 8 injection channels have logic level(+5v) control for coils that have built in igniters or systems where you wish to use an existing Igniter pack:
Option 2+6 Two channels are high current, the other 6 are logic level:
Option 4+4 Four channels are high current, the other 4 are logic level:
Option 6+2 Six channels are high current, the other 2 are logic level:
Option 8 All 8 channels are high current control channels:
Assembling when purchased from WebShop unassembled
The 0,2 and 8 IGBT-s are trivial. (the 2 IGBTs are for ignchannel 2 and 3, so only 2 clamping plates are needed in this case: the 3d line of switches has no IGBTs).
The L means logic-level (short between output and gate). The numbers are ignition channel numbers for the given physical position. EC36 is at the bottom
4 IGBT:
7
LL
6
L 3
L 2
Econoseal36 is down here
6 IGBT:
7
LL
6
0 3
1 2
Econoseal36 is down here
OLD standard - before 2006-12
The 0,2 and 8 IGBT-s were always the same.
The 4 (4+4) and 6 (6+2) options were different before 2006-12 :
Option 4+4 Four high current channels, Four logic level:
Option 6+2 Six high current channels, two logic level:
The reason this was changed is that the new scheme is much more useful with the (rarely used) "ign dualout" option.