WBO2 default Config - subpage of GenBoard/Manual/WBSensor \n
wbo2_warmup_ramp=A0 # 0.2 V/sec wbo2, warmup ramp speed [1.51 mV/sec] wbo2_warmup_target=FF # variable dropped a long ago wbo2_abs_limit=E4 # wbo2, heater absolute limit [?] (DA) wbo2_limit_maxt=A0 # wbo2, max time spent at abs_limit [262msec] (50) wbo2_fallback=B0 # wbo2, fallback V after maxt (0xC0 will heat it better than 60, especially when 350C exhaust gas cools the 750C sensor element at idle) wbo2_retry_t=06 # wbo2, retry control after [4sec] wbo2_edgetime_corr=BA # variable dropped in most recent firmwares wbo2_edgetime_min=50 # variable dropped in most recent firmwares wbo2_ri_target=96 #wbo2, target Ri (pulse amplitude) [5V/8192] absolute value: pump+ closest to pump- at startup) wbo2_heater_pid_kp=46 wbo2_heater_pid_ki=10 wbo2_heater_pid_kd=1A wbo2_heater_pid_ilimit=80 wbo2_pump_pid_kp=15 wbo2_pump_pid_ki=4E wbo2_pump_pid_kd=00 wbo2_pump_pid_ilimit=84 wbo2_ri_confidence_scale=80
Controller specific values:
- wbo2_nernstdc_target=86 # controller specific (controller not sensitive to very precise setting), usually 0x86 gives most precise 0.45V between nernst and pump-
- wbo2_pump_pw_zero=65 ## controller specific. Look up webshop mail (or calibrate for your controller for minimum pump current
Sensor specific - See GenBoard/Manual/Config/WidebandCalibration
Calibrate yourself in free air, after replacing the sensor!
- wbo2_calibration=C0