History of QuincyStraker/InjectioN
Older Newer
2015-01-01 07:00:00 . . . . MembersPage/MarcellGal [fuelpump hints checklist]
2015-01-01 07:00:00 . . . . 84-105-124-240.cable.quicknet.nl [fuelpomp issues]
2015-01-01 07:00:00 . . . . 84-105-124-240.cable.quicknet.nl [injectoroutput]
2015-01-01 07:00:00 . . . . 84-105-124-240.cable.quicknet.nl [injction setting]
2015-01-01 07:00:00 . . . . 4d6f43e8.adsl.enternet.hu [injector output sequence]
2015-01-01 07:00:00 . . . . 84-105-124-240.cable.quicknet.nl [wiring]
2008-01-28 14:28:35 . . . . 84-105-124-240.cable.quicknet.nl [pinout]
2008-01-23 13:39:53 . . . . 84-105-124-240.cable.quicknet.nl [injector]
2008-01-19 01:50:35 . . . . 84-105-124-240.cable.quicknet.nl [injection]
2008-01-19 01:48:39 . . . . 84-105-124-240.cable.quicknet.nl [injection]
2008-01-19 01:47:03 . . . . 84-105-124-240.cable.quicknet.nl [injection]


Changes by last author:

Added:
My fuel pump was running fine, 3 sec when ecu on, and 1 sec after cranking. Now ones it start running it doesn't go off. While I haven't changed anything. => pretty useless info without mcd,mct and firmware version

* see IssueReports

* check all output channels in mcd dump, disable them (FF)

** als,launch and shiftcut are input channels, those are not interesting here

* measure if output really pulls down (remove relay and measure between +12V and fuelpump output) or just relay gets stuck somehow

Deleted:
'''My fuel pump was running fine, 3 sec when ecu on, and 1 sec after cranking. Now ones it start running it doesn't go off.

While I haven't changed anything.'''