Changes by last author:
Added:
For now, primary_trigger=5 window cam-hall is used (possible because of distributer). Later maybe a HALL-HALL (with 1GT101 crankHALL, 5 or 15-1 window or similar) will be an option HALL sensor The 3 pin connector is similar but mechanically incompatible with the 3 pin AMP connector ("injector-connector" / 3pin) in webshop. The connector might fit, but the receptacles are not deep enough. Beware of this. So we reused a cutdown connector, see HALL connector color * pin, v3harness color, function, HALL-connector-color. * EC36/28 white +5V red-black * EC36/27 brown HALL green-white * EC36/26 GND/shield brown-white Note that the GND should preferrably be a separate wire in the shielded cable. So the shield would be connected on one side only. Does not matter much for HALL sensor though. |