Changes by last author:
Changed:
Injectors are connected to EC36 7-19-8-20 in order.
The fire order is 1-3-4-2. |
Firing order is 1-3-4-2. injectors GenBoard/Manual/DigitalOut/Table Injectors 1-2-3-4 are connected to EC36 7-19-8-20 : * cyl2 EC36/19 mask2 * cyl4 EC36/20 mask8 * cyl3 EC36/8 mask4 * cyl1 EC36/7 mask1 |
Is it ok?
4. channel is used for PWM iac. |
The smart way is to do the "mapping" at wiring time (wiring is done only once). That way the table is filled in an order easy to review later (done multiple times, especially if rotated to change phase). * cyl2 EC36/7 mask1 * cyl4 EC36/19 mask2 * cyl3 EC36/8 mask4 * cyl1 EC36/20 mask8 h[0]=01 02 04 08 10 00 00 00 ---- 4. channel is used for PWM iac. |