Changes by last author:
Changed:
---- |
----
20-11-2013 Help needed Engine cannot start when -2 degrees. Engine gets more and more difficult to start the lower the temperature. VEMS takes 8-12 sec to send IGN pulses out to Crane HI6 when +8 degrees outside. VEMS will not send IGN pulses out to Crane HI6 when -2 degrees outside. When or if the engine gets started, other start attemps the engine fires up after 4-6 sec. When warm no problems starting. I can see the IGN pulses from the VEMS on Crane HI6 LED indicator. Battery is 65 Amp/h and new. The problem is that VEMS do NOT send IGN pulses out when cranking in cold wheather. Look at the logfiles. If you mark between 2 missing tooth VemsTune says 59-61 tooth count, but if you count them manually there is 58 tooths. The logfiles are from cranking today at -2 degrees. Triggerlog1 http://www.vems.hu/files/PerVolvo/crank%20at%20-2%20dg%20outside-1.triggerlog Triggerlog2 http://www.vems.hu/files/PerVolvo/crank%20at%20-2%20dg%20outside-2.triggerlog vemscfg http://www.vems.hu/files/PerVolvo/camsync%205.vemscfg If I disable camsync, still no starting. The wierd thing is if I disconnect the camsync sensor and disables camsync the engine starts. After that I can reconnect the sensor and reenable camsync and the engine starts. But tomorrow when it is cold same problem I guess. It seems to me that the camsync sensor can disturb the crank trigger signal In this triggerlog with engine idle, VemsTune reports 58 and 59 tooth count, but when I manually count them there are 58 tooth counts. http://www.vems.hu/files/PerVolvo/trig%2058-59.triggerlog ---- |