2006-03-12 23:35:16 . . . . MembersPage/MarcellGal [5 high-Z injectors wired in 1 bank would work, but not recommended]
2006-03-12 20:59:51 . . . . dsl51B7A1ED.pool.t-online.hu [why not 5injectors on 1 channel??]
2006-03-12 20:31:42 . . . . dsl51B7A1ED.pool.t-online.hu [moved old q]
2006-03-12 20:23:53 . . . . MembersPage/MarcellGal [staging notes]
2006-03-12 20:22:27 . . . . MembersPage/MarcellGal [staging hint: connect secondary grouped to 2+3]
2006-03-12 20:20:01 . . . . MembersPage/MarcellGal [staging h[0] injection sequence]
2006-02-25 03:57:02 . . . . MembersPage/NanassyPeter [is this ok?]


Changes by last author:

Changed:
** connected grouped to (F,F,F), (G,G) (connecting 3 in parallel is no problem, because injectors are 12..14 Ohm high-Z)
** connected grouped to (F,F,F), (G,G)

** connecting 3 in parallel is no problem, because injectors are 12..14 Ohm high-Z

** the injector-closing (flyback voltage on powerflyback) is same no matter if 2 or 3 injectors are connected to a given channel. With 3 channels, there is no risk of ruining the output with high-Z (3A load current vs. 9A capability; 3A flyback current vs 4..9A capability - capability depends on pwm-ing configuration)

** 5 injectors (even of the staging set) to 1 INJ channel is not recommended.

*** if you configure h[0] to inject together with the primary set (eg. as an experiment to find the equivalent pulsewidth: eg. 3.3 msec with both sets of equal size running is equivalent quantity as 6 msec of the primary set only) => the supply rail will fluctuate more, and fuel quantity will not be as even as with 2+3.

*** If you wire 2+3, you can still easily apply both banks connected to same output if you badly need the output channel in the future.

Changed:
8 2 1 4 16 128 00 96 decimal (as in MegaTune)
8 2 1 4 16 128 0 96 decimal (as in MegaTune)
Deleted:
Q

OK

Nice,but the reason i would like to run this on 1 FET:

*i will need free INJ FETs in the future

*is it really the same opening if connected 2 vs. 3 to 1 INJFET?

*if an INJFET dies,we will notice it if all injectors is connected to it,but if 2 injfets are used,its much harder

Can i connect 5 injectors to 1INJ channel????

Changed:
do you have any experience with fuel staging?How can i set up the unused (INJ 7,6,5) fets to drive the staged ones?I read the relevant page,do i have to insert them in to h(0) tables last place?my current h0 looks like this

----

TODO: cleanup according to above - it seems all is answered above

Fuel staging

How can i set up the unused (INJ 7,6,5) fets to drive the staged ones?I read the relevant page,do i have to insert them in to h(0) tables last place?my current h0 looks like this

Added:

rotating the injection phase (this table is 288 degrees earlier compared to the 8 2 1 4 16 ... above) shouldn't make a big difference (at the end of the tuning! it effects the best VE table slightly), so leave it the way you had when you tuned