Changes by last author:
Changed:
Firmware 1.1.91 |
Firmware 1.2.38
Trigger Setup Had to modify old v3.3 board hardware from Hall to VR. Problem: Primary trigger VR is OK but no secondary trigger show up on triggerlog. Solution: reviewed the hardware by checking following items for VR setup: *Primary Trigger VR ** remove R30 OK ** solder SJ6 OK ** solder JP2-JP7 OK *Secondary Trigger VR ** solder LM1815 OK ** solder SJ7 OK ** wire EC18pin12 --> pin3 2nd LM1815 OK ** solder 1k smd pulldown resistor between VRinput-GND OK ** connect LM1815 pin5 to +5V OK ** R182=0 OK ** removed C103 was the final trick, without removing I had not sec trigger Help! Can someone help me with analysing triggerlog? Seems there are some problems with Too many PTrig, LessPTrig and LessStrig http://www.vems.hu/files/Marteleur%20Tim/v3.3_u000374-2020-12-28-21.42.58CamSyncOK.triggerlog http://www.vems.hu/files/Marteleur%20Tim/v3.3_u000374-2020.12.26-19.23.21CAM2.vemscfg ---- |