Changes by last author:
Added:
Audi A8 -95 config stock trigger
Primary trigger: 60-2 Secondary trigger: Home signal 60deg before #1TDC in the work stroke. Injectors: 200cc Bosch injectors high ohm. Ignition: 8 direct fire 0.7ohm coils 2mS preliminary dwell. Clean this: _jorgen: Marcell, could you explain the tooth widh concept? _jorgen: Is that in degrees or is that in 'phase' units? mcel: engphase units. reset_engphase_after (usually 240 or 216) is 720 degrees mcel: but twidth1 and twidth2 is not used IIRC _jorgen: Yeah, I figured that out. _jorgen: But I saw notes about twidth1 and twidth2 beeing used when running with cam sync. mcel: it's best to configure them, takes nothing _jorgen: To me it seemed like the phase was incrementeed with twidth every time it saw a tooth. _jorgen: But it's not obvious how to configure them. _jorgen: Is it real degrees or is it configured in 720/240th of a degree? mcel: the keyword is engphase mcel: I see that engphase is updated, but I don't see any place where it would be used (except lcd_display), even for camsync setup mcel: 720/240 degrees mcel: that is twidth1=2 twidth2=6, reset_engphase_after=0xF0 for a 60-2 _jorgen: But there is some code that say that the first primary trigger after cam sync is a specific engphase. If engphase is not used the camsync will be ignored. mcel: that is twidth1=3 twidth2=6, reset_engphase_after=0xD8 for a 36-1 mcel: we should document that in wiki |