History of MembersPage/GunnarReynisson/BigMotronicPin
Older Newer
2024-12-19 04:38:11 . . . . 84-236-30-80.pool.digikabel.hu [logiclevel]
2024-12-17 08:01:03 . . . . 178-164-225-121.pool.digikabel.hu [ign cyl nr]
2024-12-17 07:47:02 . . . . 84-236-106-17.pool.digikabel.hu [disa valve]
2021-10-14 13:55:41 . . . . dslb-092-077-180-164.092.077.pools.vodafone-ip.de [M42 DISA Valve mod requested]
2019-05-27 15:24:52 . . . . 188-143-5-189.pool.digikabel.hu [note: Siemens DME MS41.0]
2018-08-04 09:05:42 . . . . 62-165-192-122.pool.digikabel.hu [M52 notes, emphasize swap cam-sensor]
2017-12-08 16:02:03 . . . . IN-84-15-183-034.bitemobile.lt [some thoughts]
2017-12-06 12:13:41 . . . . catv-86-101-250-44.catv.broadband.hu [could not reproduce buzzing / prelling]
2017-11-26 10:10:32 . . . . host-212-139-68-232.static.as9105.net [M52 PnP Issue]
2016-01-29 17:19:25 . . . . catv-80-98-222-153.catv.broadband.hu [exact frequency question]
2015-11-26 11:05:46 . . . . catv-80-98-222-153.catv.broadband.hu [minor cleanup, mention replacement sensor]
2014-11-15 13:49:56 . . . . GunnarReynisson [M52 Trigger solution required]
2013-05-28 22:33:17 . . . . GunnarReynisson [Updated with M50 non vanos wiring PDF]
2012-04-05 21:35:42 . . . . host-92-20-227-244.as13285.net [M52 BMW Engine scope output]
2010-08-04 13:27:44 . . . . host-92-14-157-158.as43234.net [88pin motronic update]
2009-02-11 11:15:39 . . . . MembersPage/GunnarReynisson [found a supplier]
2008-03-03 00:49:23 . . . . cpc3-derb8-0-0-cust955.lei3.cable.ntl.com [added]


Changes by last author:

Changed:
ID 17240 -
(order-ID 17240)
Changed:
* JPT88 pin 25-23-24 (for ign cyl 1,2,3)

* and JPT88 pin 50-52-51. (for ign cyl 4,5,6)

* JPT88 pin 25-23-24 (for ign cyl 1,2,3 on 6 cyl M50-nonvanos)

* and JPT88 pin 50-52-51. (for ign cyl 4,5,6 on 6 cyl M50-nonvanos)

On v3/13808 (and 13041) the following ignoutputs are Logic-level (no IGBT - very easy to test with DVM DC voltage measurement with VemsTune if coils are disconnected, save config; outputs temporarily removed from ignouts and set as misc output which can be inverted by 1 click; if set as ignout => testing only makes a short pulse, so possible with LED+protection or special measurement tools, but if removed from ignout and set as MISC output than output stays indefinite time so he can measure as long as he likes, just make sure to upload original config or configure back manually and verify before connecting coils to prevent burning coils):

* JPT88/pin25 (ignch0 logiclevel)

* JPT88/pin52 (ignch6 logiclevel)

* JPT88/pin24 (ignch2 logiclevel)

* JPT88/pin51 (ignch1 logiclevel)

* Not connected (EC36/pin11 no IGBT, not logiclevel, not connected, internally free for any custom usage if needed)