History of MembersPage/FredrikEngzell
Older Newer
2019-03-23 17:31:49 . . . . c80-217-97-144.bredband.comhem.se [Updated the errors.]
2019-03-16 08:04:32 . . . . c80-217-97-144.bredband.comhem.se [Answer to the comment on TPS]
2018-12-30 11:02:41 . . . . 188-143-18-182.pool.digikabel.hu [minor hints (and formatting)]
2018-12-28 12:59:57 . . . . 194-236-7-11.customer.telia.com [Added some system info]
2018-12-10 18:27:36 . . . . c80-217-119-26.bredband.comhem.se [Help request TPS no 5v]
2018-12-10 18:25:25 . . . . c80-217-119-26.bredband.comhem.se [Filled first page.]
2018-12-10 18:25:24 . . . . c80-217-119-26.bredband.comhem.se [Filled first page.]


Changes by last author:

Changed:
The system is working fine except the 28+29 pin on the Econoseal 36 at 5V.
The system is working fine except the 28+29 pin on the Econoseal 36 at 5V. I have tested the output from pin 28+29 and only very low,0.13v, is comig out of the box.

I think the 5v dc regulator has been broken.

Added:
-This is the problem -they do not work OK and TPS is dead.only getting 0.13v from both 28&29 so Ithink the Voltage regulators inside are dead.
Added:
-I don not want to fiddle around inside the box because I am not that capabel around electronics.