Changes by last author:
Added:
----
VR trigger polarity first see InputTrigger/TriggerLog |
>>>>>>>>>>>>>>>>>>>>> |
Without scope (Hungarian)
* egy DVM-el 200 mV DC állásban is meg lehet nézni 10 perc alatt. * Normal kereket feltetelezve (hianyzo fog, nem pedig tele fog) ha közelited a kalapacsot, + mV -ot mersz. ** Ha tavolitod, akkor - mV-ot (minusz-t). * Persze csak rövid ideig, amig mozog, de azért ezt lehet látni. * Forditva nem jo ! |
---- |
We have some problem at ide, the 1000 injectors and itb wont let lambda to get under 0.85..around 2ms opening time (the minim is 1.55ms for thees injectors with balance power resistor). |
We have some problem at idle, the 1000 cc/min injectors and itb wont let lambda to get under 0.85..around 2ms opening time (the minim is 1.55ms for thees injectors with balance power resistor). |
Xenon gets everything crazy, most probably high frequency disturbs VEMS on the +vbat side...or the VR sensor, not likely cos every sensor is shielded... |
Xenon headlights get everything crazy, most probably high frequency disturbs VEMS on the +vbat side...
* or the VR sensor, (unlikely cos every sensor is shielded) |