Changes by last author:
Added:
Here is example how to set inline 5cyle engine only run on 60-2 sensor(vr).
Injector 1=vems inj0 .. Injector 5=vems inj4 COP 1=vems ign0 .. COP 5=vems ign4 Firing order is:1-2-4-5-3 So you need to fire 5 time per crank rotation, so you get wasted spark but on one cyl(COP). For volvo t5 you need to set: primary trigger rissing trigger toth: 5 next toth:12 (60/5) h1 table=0 48 36 24 12 ign output=ign0 ign3 ign2 ign1 ign4 Becouse you have twice more ign events, you need to put double less constant for rpm, so 1200 and you need to put divider 2 on injectors. Here is config( firmware 1.1.47v2). That config isn't maped so don't use VE and spark table. |