History of MembersPage/AnttiKo
Older Newer
2024-04-20 14:41:16 . . . . mobile-access-2e844a-230.dhcp.inet.fi [Cam timing fixed]
2021-01-30 15:41:53 . . . . mobile-access-2e8415-24.dhcp.inet.fi [I-button installed]
2021-01-01 21:43:28 . . . . mobile-access-2e844e-166.dhcp.inet.fi [Cam timing info]
2020-12-18 18:25:02 . . . . 87-100-210-162.bb.dnainternet.fi [Moved the solved problem case to sub-page of my wiki]
2020-12-18 16:09:20 . . . . mobile-access-2e8425-247.dhcp.inet.fi [Fault was found]
2020-12-18 14:09:59 . . . . customer-185-091-251-159.solcon.nl [reviewed vemslog, pointed to heater test]
2020-12-18 11:47:37 . . . . mobile-access-2e8425-247.dhcp.inet.fi [Added information on new log file]
2020-12-18 09:09:50 . . . . customer-185-091-251-159.solcon.nl [ego log review, provided instructions for detailed cause find]
2020-12-17 18:24:43 . . . . mobile-access-2e8425-247.dhcp.inet.fi [Added description for link to my log]
2020-12-17 18:21:16 . . . . mobile-access-2e8425-247.dhcp.inet.fi [link to my file section]
2020-12-17 13:42:13 . . . . 193.210.0.12 [Added sensor data]
2020-12-16 21:53:15 . . . . mobile-access-2e8425-247.dhcp.inet.fi [Updated information on the build]
2020-12-16 08:02:00 . . . . 193.210.0.12 [Project information]
2020-12-16 06:54:02 . . . . 193.210.0.12 [Project information]
2020-12-16 06:44:56 . . . . 193.210.0.12 [Project information]


Changes by last author:

Changed:
*2020 12 16 To do

- Cam always on retarded position. Too much overlap in 4500 rpm and onwards. Need to change cam timing to correct.

*2023

- Cam timing fixed