Changes by last author:
Added:
Free air calibration procedure
First calibrate 1st WBO2 with * Wideband settings / 2nd WBO2 = disabled * free air (of course) Than enable 2nd WBO2 and calibrate "Second" WBO2: * Wideband settings / 2nd WBO2 = disabled * free air (of course) ---- NOTE (errata): * if 2nd WBO2 is enabled * always restart ECU before "Start calibration" ** it was reported that with fw 1.2.31 Dual WBO2 (2nd WBO2=enabled) Tools/WBO2 calibration Stop and reStart calibration after previous attempt and >1 minute: only 2nd heater starts to heat rampup, even if "FIRST" channel is chosen in VT (weird). ** "Start calibration" after ECU reboot => both heaters ramp up ** But recommended to calibrate first WBO2 with 2nd WBO2=(temporarily) disabled, see above. ---- If in doubt, check that the wires go to the correct WBO2. * pump- and +12V are shared, but other signals should be connected to the appropriate nernstinput, pump+ and heater outputs. |