IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: 440cc@3bar injectors I got 7.3mS required fuel for petrol and 10.6mS for E85. Firing order is 1-3-4-2. injectors GenBoard/Manual/DigitalOut/Table Injectors 1-2-3-4 are connected to EC36 7-19-8-20 : * cyl2 EC36/19 mask2 * cyl4 EC36/20 mask8 * cyl3 EC36/8 mask4 * cyl1 EC36/7 mask1 h[0]=02 08 04 01 10 00 00 00 The '''smart way''' is to do the "mapping" at wiring time (wiring is done only once). That way the table is filled in an order easy to review later (done multiple times, especially if rotated to change phase). * cyl2 EC36/7 mask1 * cyl4 EC36/19 mask2 * cyl3 EC36/8 mask4 * cyl1 EC36/20 mask8 h[0]=01 02 04 08 10 00 00 00 ---- 4. channel is used for PWM iac. Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.