### ### ## ## ## ## ## ## ## ## ### ##
#### ## ## ###### ## ####
____ | __ ) | _ \ | |_) | |____/
_ _ ( ) ( ) | |/'/' | , < | |\`\ (_) (_)
____ | _ \ | |_) | | _ < | |_) | |____/
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: VEMS Round with Motronic 7.1 VEMS Round using the following input: - WBO2 - EGT - Analog 1 --> 10 bar oil pressure sensor '''Q''': Can't get my head round calibrating this. Can I have some help please with the configuration for analog input. The sensor is linear. Calibration from vendor: Sensor Output 150 PSI Gauge 0.5 volts at 0 PSI gauge pressure (atmospheric pressure) 4.5 volts at 150 PSI gauge pressure (150 PSI above atmospheric pressure) 150 psi sensor: pressure = 37.5 * voltage - 18.75 Any way to display in bar? '''Q''': 0.5V=0PSI=0bar, 4.5V=150PSI=10.34bar, with the AnalogInputCalibrationWizard, I get calibration 129, offset 12. Correct? * As we talked about this in person I would like to add that zeroing out the first 2 values of the curve is not a good idea because it will interfere with the slot button (it will not allow pressing). - Analog 2 --> 400kPa VEMS Map sensor * Apparently there is no way to display *BOTH* analog outputs on the display. I would like to see both boost and oil pressure on the slots. ** '''Very''' outdated information. If you need to display both analog inputs on the round display at the same time, '''just use the latest round fw''' (and in VT Preferences, update ini files from web, of course) and [http://vems.hu/vt/help/round/round_dialogs.html read VT help]. Support for ANALOG2 on display was added a long time ago. ** Latest nightly VT only supports using ANALOG2 in Display Mode, Main Display Settings do not have ANALOG2 at all and if we configure ANALOG2 in display mode, the main display settings show an empty string in the dropdown. Outputs: - PWM0 -> reference RPM drive warning led for shiftlight - PWM4 -> reference RPM drive "shift-now" led for shiftlight ---- * Example settings for blinking shift-light on PWM0 engaging at 1502rpm, blinking 0.95Hz http://vems.hu/dave/shiftlight_blink_1500rpm.png * Example settings for normal shift-light on PWM4 engaging at 3008rpm http://vems.hu/dave/shiftlight_normal_3000rpm.png '''A''': Provided elaborated settings above (tested). '''Q''': I noticed that the output starts sending a signal around 200rpm earlier than it should probably to reach target rpm. Any way around this? '''A''' Yes use a more aggressive control slope, use Kp = 255, Ki = 255, iLimit = 5 - DB * Tested the settings above and they work fine * traditionally the maximum target '''idle RPM''' that can be configured is 4080. * '''max configurable idle RPM target was increased to 16320 RPM with round fw 1.5.10''' (max displayable RPM is 15999 so above that one would need to cheat, eg. 1/2 or 1/10 of real RPM, eg. for a high-revving small gas turbine) ** [http://vems.hu/download/v3gui/dev/ VemsTune-Install-2015-04-04.exe] is needed for it (normally Preferences / "Update ini from web" is also part of the procedure) ** since roundv2 fw 1.5.10 has AIM, it presents itself as 0.5.10 ( that is OK ) Please either modify the ini files or the firmware. * I did not modify the ini files because I don't want to crash the firmware with an integer overflow in case int bounds checking is not implemented. ** this lacks any ground. By changing ini (eg to invalid formulas, unmatched '() {}' or alike ), only VT can be crashed. Firmware cannot be crashed. ** Even if firmware were partially uploaded, or could be crashed somehow: it could be recovered through "round emergency revival" via serial bootloader ** such "crash" never happened with round fw *** even for v3 (which had more firmwares during the years, and 30 times more functions), only 1 invalid config - among many tests when complete garbage was uploaded (to many different firmwares) - caused firmware infloop (not insidiously unexpectedly, but from startup) that needed serial-loopback to recover (that was fixed years ago) **** Thanks for the fast fix. I did not state it will crash, just wanted to avoid modifying anything that would lead to a crash and recovery, that's all. ---- * Linear wideband output is connected to Motronic 7.1 for data-logging. (This Motronic ECU is dual-narrowband with dual EGTs for mixture preparation.) ** vout_conf=5 and conversion configured in Motronic as advertised on the AfreshTiny/VoltageOutput page: 0V -> 10 AFR 5V -> 20 AFR To calculate the factor, we first must remove the offset. We do this by subtracting the value at 0v from the value at 5v. 20-10=10 This number is the value at 5v without the offset applied. To get the value per voltage we just divide this by 5 (volts). 10/5=2 Our factor is 2 and the offset (value at 0v) is 10. Now we just apply the factor for the particular RAM variable that we are working with in ME7. uushk_w voltage factor is 0.004883, so we multiply this by the voltage to AFR factor that we calculated for our new input. 0.004883*2=0.009766 ME7Logger applies a negative offset, so in order to use a positive offset we just need to flip the sign. The values that we have been working with are AFR, therefore to convert our input to AFR: Factor : 0.009766 Offset : -10 - RPM input is coming from the Motronic RPM signal (instrument cluster) '''Q''': Can this even be configured or do we need a crank signal?! If that's the case the documentation (Help) should be change to state something other than "RPM Signal". '''A''': Yes RPM signal from dash is fully supported, [http://vems.hu/vt/help/round/round_rpm_input_settings.html more info in VT help Rpm Input], example for 4cyl: rpm_toothcount=02 for a 4 cyl 2 events per rotation '''Q''': Any pointers on configuring it for 6 cyl 4stroke V6 engine? Setting it to 60-2 wheel does not work obviously. Thanks '''A''': For 6cyl 4 stroke, 6 rpm events per cam rotation, 3 per crank rotation the correct rpm_toothcount=03 '''Q''': With above settings it is not working properly still, vemslog available at: http://nerd.hu/r2.1_4513-2015.04.02-12.42.18.vemslog Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.