### ## ### ## # ##### ## ## ## ## #### ###
## ## ##### ## ## ## ## #####
_________ \__ __/ ) ( | | | | | | | | )_(
###### # ## # ######
##### ## ## ## ## ##### ## ##
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: After using piggyback ECU's such as Morristech TSI and AEM Fic 6/8 and not satisfied, I decided to go standalone ECU. Engine code: S50B32 Specs: 6 cylinder in line Infinite variable camshaft angle on both intake and exhaust(VANOS) displacement (cm3): 3201 JE pistons 8.5:1 compression ratio Forged ARROW connecting Rods Coil on plugs and full sequential Stock cams GT37/40 hybrid turbo 3 vr sensors Crank 60-2 Exhaust 6+1 Intake 6 Engine management: VEMS V3.6 Firmware 1.1.96 Dual Vanos Enabled VEMSTUNE 1.2.4 ---- '''Vanos preamble''' * '''Forget cam-adjustments until the engine drives like a charm''' The car already drives like charm ** so well you would take the family on a holiday: it wouldn't stall, or be nervous or misfire. ** Maybe connect light-bulb only (between PFET outputs and GND, so you can see in operation: which operates when, while you watch "sectrig position" and play with target table). * in '''BMW''', dual outputs actuated for sectrig (and dual for third trig). '''Basic operation is simple, in short:''' ** '''If measured "sectrig position" is lower''' than adjusted target (in the "sectrig position" table, historically called "intake" but actually sectrig is exhaust for BMW) '''then Output-A''' is activated to advance cam (remember it by: A="advance") ** '''if measured "sectrig position" is higher''' than adjusted target, then '''Output-B is activated''' to retard cam. ** third trigger is similar, but with own "Output-A" and "Output-B" outputs for the other cam (the exact econoseal pin must be configured according the setup). ** after reading the above 3 times (and understanding it), see http://vems.hu/vt/help/v3/v3_camshaft_angle_control.html for more details. ---- '''Vanos outputs''' - 4 PFET outputs requested * since PFET's switch to +12V (not to GND as NFETs !!!) test all 4 PFET outputs with '''lightbulb connected between output and power-GND''' (you have all 5 grounds connected, right ???) ** eg. breaklight max 25W, 2A, min 6 Ohm or perhaps somewhat lower when cold * first disable the camshaft-angle-control outputs, and use misc1 (or misc2) function to test the outputs (eg. with TPS). * if all 4 PFET outputs work with misc function-test ** disable the misc output and configure the camshaft-angle-control outputs ** if you have problem with Vanos, add 2 or 4 LEDs (series resistor and series 1n4007 diode or almost any type of diode) so you can see which ones are active (2 DVM is also OK, just connect them so you don't have to hold !). ** if the trigger position shows the hydraulic does not actuate even though the ECU applies voltage, maybe the 2 solenoids are reversed (or go to the intake instead of exhaust) ! * capture vemslog and take note of your comments '''Document your wiring of the 4 PFET outputs here:''' * EXHAUST cam (sectrig) solenoid A (advance: DME pin 22 to EC36 pin 3). * EXHAUST (sectrig) Solenoid B (retard: DME pin 21 to EC36 pin 15) * INTAKE (third trigger) Solenoid A (advance: DME pin 67 to EC36 pin 31) * INTAKE (third trigger) solenoid B (retard: DME pin 72 to EC36 pin 30) '''Link the vemslog or vemscfg here !''' - so we can compare to the wiring There could be 3 scenerios, your sentences would be like: * see ... vemslog, at sec 17.3 I apply 12V maually to hydraulic actuator ... (ECU outputs DISCONNECTED) but neither sectrig position nor third trig position moves according to vemslog (=> triggerlog will be needed for sure, and perhaps sg wrong with the hydraulic actuator HW?) * I disabled camshaft angle outputs (both third trig and sectrig) and tested PFETs with the miscX function, but ... does not work (the other 3 works as expected). * see ... vemslog, at sec 17.5 I measure ... on EC36/.... and ...on EC36/.... although the third trig target is configured .... higher/lower than the third trig position Your Vanos wiring is needed (on your page) in any case, and most likely .vemslog (and .triggerlog also). ---- I kept the OEM harness and sensors to have the installation clean and OEM like. ---- Ignition coils wiring: done Important note: traversed according the arrows (that point up) in VemsTune ---- '''TODO: testing the Vanos and camshaft movement.''' Camshaft target table is '''directly related to the "sectrig position" and "third trig position"''' gauges: * higher values advance, ** lower values retard I'm not sure I understand this well: (which part ?) **this part Measured = 0 ... target - 2 deg - PWM-ing range : OutputA active and OutputB inactive , Cam pulse too late Measured = (target - 2 deg - PWM-ing range) ... (target - 2 deg) : OutputA active and OutputB PWM-ing ( closer to target = PWM duty higher ) Measured = (target - 2 deg) .... (target + 2 deg): OutputA and OutputB active Measured = (target + 2 deg) .... (target + 2 deg + PWM-ing range): OutputA inactive and OutputB active Measured = (target + 2 deg + PWM-ing range) ... 360 deg: OutputA PWM-ing ( closer to target = PWM duty higher ) and OutputB active , Cam pulse too early Just document your wiring and measurements, and '''given the captured vemslog''' (preferrably with some comment, like "I disconnected ECU output and at 17 sec applied 12V manually to exhaust cam/... solenoid") we can inspect and review ! Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.