_ _ ( ) ( ) | `\| | | , ` | | |`\ | (_) (_)
## ### ## ## ####
##### ## ## ## ## ##### ## #####
#### # # ###### # ####
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: After using piggyback ECU's such as Morristech TSI and AEM Fic 6/8 and not satisfied, I decided to go standalone ECU. Engine code: S50B32 Specs: 6 cylinder in line Infinite variable camshaft angle on both intake and exhaust(VANOS) displacement (cm3): 3201 JE pistons 8.5:1 compression ratio Forged ARROW connecting Rods Coil on plugs and full sequential Stock cams GT37/40 hybrid turbo 3 vr sensors Crank 60-2 Exhaust 6+1 Intake 6 Engine management: VEMS V3.6 Firmware 1.1.96 Dual Vanos Enabled VEMSTUNE 1.2.4 ---- '''Vanos outputs''' - 4 PFET outputs requested * test all 4 PFET outputs with lightbulb connected between output and power-GND (you have all 5 grounds connected, right ???) ** eg. breaklight max 25W, 2A, min 6 Ohm or perhaps somewhat lower when cold * first disable the camshaft-angle-control outputs, and use misc1 (or misc2) function to test the outputs (eg. with TPS). * if all 4 PFET outputs work with misc function-test ** disable the misc output and configure the camshaft-angle-control outputs ** if you have problem with Vanos, add 2 or 4 LEDs (series resistor and series 1n4007 diode or almost any type of diode) so you can see which ones are active (2 DVM is also OK, just connect them so you don't have to hold !). ** if the trigger position shows the hydraulic does not actuate even though the ECU applies voltage, maybe the 2 solenoids are reversed (or go to the intake instead of exhaust) ! * capture vemslog and take note of your comments '''Document your wiring of the 4 PFET outputs here:''' * * * * '''Link the vemslog or vemscfg here !''' - so we can compare to the wiring ---- I kept the OEM harness and sensors to have the installation clean and OEM like. ---- Ignition coils wiring: done Important note: traversed according the arrows (that point up) in VemsTune ---- The harness was ready and installed on june 13th 2012. Sensors were tested OK. Ignition also OK on the test mode: ignition out 0 drives cyl #1 coil... firing order 054321-->153624 First attempt to start: the ECU asked for Password which I had not. VEMS shop sent it to me then another problem was that ECU was in Safe Mode. Ignition and injection outputs were disabled. Solution: just upload the config file again. First start: unsuccesful. Big pop sound on the exhaust. I checked the sparks and everything was OK. I tried to reduce cranking VE in case the engine was flooded. No succes. June 15 I verified if the ignition sequence was right. Method: unplug the first spark plug and just let it on the spark hole. Put a spare spark plug on the corresponding coil plug. Start the car and check if spark occurs on the compression stroke. Result: The spark did not occur on the compression stroke so I had to shift up the outputs (ignition outputs table) The car started right after shifting the outputs 3 times. The firing order starts according to the cam pulsetrain (often not cyl1 !). Now the firing order is 624153 (same as 153624, it's no different, it's a circle !) '''TODO: testing the Vanos and camshaft movement.''' Camshaft target table is '''directly related to the "sectrig position" and "third trig position"''' gauges: * higher values advance, ** lower values retard I'm not sure I understand this well: (which part ?) Dual Vanos Output type: Two outputs used for intake and two (optional) for exhaust. Use injector or ignition output ( 4ohm => 3A current ) Control method: Under 450 RPM : OutputA and OutputB inactive Measured = 0 ... target - 2 deg - PWM-ing range : OutputA active and OutputB inactive , Cam pulse too late Measured = (target - 2 deg - PWM-ing range) ... (target - 2 deg) : OutputA active and OutputB PWM-ing ( closer to target = PWM duty higher ) Measured = (target - 2 deg) .... (target + 2 deg): OutputA and OutputB active Measured = (target + 2 deg) .... (target + 2 deg + PWM-ing range): OutputA inactive and OutputB active Measured = (target + 2 deg + PWM-ing range) ... 360 deg: OutputA PWM-ing ( closer to target = PWM duty higher ) and OutputB active , Cam pulse too early Just document your wiring and measurements, and '''given the captured vemslog''' (preferrably with some comment, like "I disconnected ECU output and at 17 sec applied 12V manually to exhaust cam/... solenoid") we can inspect and review ! Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.