### ## ## ##### ## ## ## ## ######
## ### ## ## ## ######
## ## ##### ## ## ## ## ###
_________ \__ __/ ) ( | | | | | | | | )_(
_ | | _ | | | |_| | \___/
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: Date. 07-10-13 Problem with 6 + 1 trigger signal. Wrong RPM showing. Trigger fail. Pls. Help. http://www.vems.hu/files/qualitec/Faling%20-%20faling%20-%2012%20+%201%20-%20100%20RPM%20-%20long%20time%20to%20sync%20-%203%20ign%20output.triggerlog http://www.vems.hu/files/qualitec/Faling%20-%20faling%20-%2012%20+%201%20-%20100%20RPM%20-%20long%20time%20to%20sync%20-%203%20ign%20output.vemslog http://www.vems.hu/files/qualitec/Faling%20-%20faling%20-%2012%20+%201%20-%20100%20RPM%20-%20long%20time%20to%20sync%20-%206%20ign%20output.triggerlog http://www.vems.hu/files/qualitec/Faling%20-%20faling%20-%2012%20+%201%20-%20100%20RPM%20-%20long%20time%20to%20sync%20-%206%20ign%20output.vemslog http://www.vems.hu/files/qualitec/Rising%20-%20Rinsing%20-%2012%20+%201%20-%20100%20rpm%20-%206%20ign%20output.triggerlog http://www.vems.hu/files/qualitec/Rising%20-%20Rinsing%20-%2012%20+%201%20-%20100%20rpm%20-%206%20ign%20output.vemslog http://www.vems.hu/files/qualitec/Vems_mitsu.png -Anders Amby ---- Qualitec Denmark I have this BMW M62B44 engine. http://vems.hu/files/MembersPage/Qualitec/BMW_M62B44_triggerlog.png Can I run it with the orginal CAM sensor that has 4 cam signals ? Yes. * '''tooth 7''', 16, 46 in one half (will sync on the sectrig pulse after tooth7) * tooth 38 in the other half ** Seems like an easy case: set "Ignore secondary trigger pulses above" (secignore) to 9 (or 10), in "Secondary trigger" settings, this should allow triggering correctly * Have you set the primary trigger position yet? I have done a few M62B44 engines and found primary trigger to be at 70deg. * Also make * Sectrig min angle - 0 * Sectrig max angle - 360 * Try another trigger log and report back (GunnarReynisson) Or should I remove 3 of the cams. Please see: * [http://www.vems.hu/files/MembersPage/Qualitec/v3.3_u006867-2013-04-29-21.37.20.triggerlog trigger log] * [http://www.vems.hu/files/MembersPage/Qualitec/v3.3_u006867-2013.04.29-21.37.48.vemslog vemslog] -Anders Qualitec.dk Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.