__ __ \ \/ / \ / / \ /_/\_\
### ##### ## ## ## ## ## ## ## ## ######
____ / __ \ | | | | | | | | | |__| | \___\_\
##### ## ## ## ## ##
## ## ## ## #### ## ## ## ##
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: Testing the v3.3 units purchased recently (#316, #317, #328 & #360) with this: http://www.mmcompsys.com/download_zone/6_sensors/SEN.pdf Magnetti Marelli sensor - which is a common sensor used by the likes of Omex and MM themselves. Its resistance was measured at ~620 Ohms. * A scope trace shows a good AC signal ~(+/-10V) on VR InputTrigger ** measure the input signal mean value, in DC setting. Eg. if the signal just slighly goes under 0V (eg. minimum is -20mV) for some reason, that would explain all. A '''scope in AC mode does not show this'''. *** Voltage measured at 9.2VAC, 0VDC * same config (from MembersPage/JimW/ExampleConfig ). ** please issue the (Man) mdv, mdV, mcd and mct '''for each''' and save the result, and publish. Very important to see the config that was actually read back *** Results are here [http://vems.hu/www.vems.co.uk/VEMSInstalls/Unit317Result.txt Unit 317] [http://vems.hu/www.vems.co.uk/VEMSInstalls/Unit328Results.txt Unit 328] [http://vems.hu/www.vems.co.uk/VEMSInstalls/Unit360Results.txt Unit 360] * all have been loaded with firmware v1.0.23 and the * verify firmware integrity (eg. prog.pl without "w" option) '''for each''' *** All verified ok, no errors * if you unclamp any ** check resistor ad LM1815 pin7 (first check that it exists, than maybe measure resistance, should be 100..180k) ** with scope, '''measure on LM1815pin3 and LM1815pin12'''. DC mode is needed to see if signal goes below GND ** check LM1815pin5: (the 3-pad SMD jumper) isn't it connected (solderblob) to either GND or +5V ? It shouldn't, and it's unlikely to explain anyway. ** don't clamp it unless the problem has been identified and fixed * #316 (primary&secondary VR) and #328 (VR primary/Hall Secondary) read the engine speed perfectly * #317 & #360 show no engine speed ** there has never been a problem with primary trigger with assembled controllers earlier (they get tested, with appr +-5V signal, lower than yours), so 2 out of 4 is extremely surprising, suggests another round of careful testing and reporting details. ** publish a few seconds of the serial-output after ''Man mdf01 mdkff'' when the trigger signal is applied. This reveals if the trigger gets input. *** Logs are here [http://vems.hu/www.vems.co.uk/VEMSInstalls/Unit317.log Unit 317 output] [http://vems.hu/www.vems.co.uk/VEMSInstalls/Unit328.log Unit 328 output] [http://vems.hu/www.vems.co.uk/VEMSInstalls/Unit360.log Unit 360 output] Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.