# ### ## # # # # # # #
## ## ## ## ## ####
______ | ____| | |__ | __| | | |_|
____ / ___| | | _ | |_| | \____|
|\ /| ( \ / ) \ (_) / \ / ) ( | | \_/
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: Audi PnP box '''aan/16082''' no spark. Marius Helmersen Norge Audi S4 AAN. Ecu installed but they have * '''no spark while cranking'''. * They '''have spark in test mode'''. ** so the outputs seem good; the config or trigger input seem to be the problem Any ides why there is no spark? * maybe ordered v3/16082 with some special, eg. HALL/HALL input ? The '''correct order of installation/testing''' * is to '''test inputs, independently of outputs: with outputs disconnected''', or disabled (removing fuses is easiest). ** including input-trigger(s), of course''' ---- '''Trigger voltage measurements''' * primtrig-VR (crank 135 pulse) DC voltage ? ** same with both ECU-s ? * sectrig crankhome-VR * cam-HALL DC voltage ? (when lo and when high) '''NEEDED: Config''' will be uploaded later. * Good, because it seems either config is the problem (which can be reviewed when uploaded); ** or trigger input; which can be tested on site. (capture and publish triggerlog, see InputTrigger/TriggerLog ) ** if no triggerlog pulses, '''disconnect the HALL sensor and insert temporary wire between GND and sectrig cam-HALL signal''' (assuming cam-HALL inverter, which is standard). => try again. Car is also tested using box AAN 3742 and the car is running perfect. * not a substitute for config and triggerlog, but useful info. ** note: the HALL of 3B can be outside the crankhome-VR, but not for the AAN. So not very likely in this case, esepecially if runs well. ** note: do the measured input trigger voltages (or better: waveforms) differ with the 2 ECU-s ? * what '''OscilloScope is on-site ?''' (now obligatory). Please make some ESD precautions, and follow install steps (including notes of verifications/measurement). Apparently running into more issues recently (of different kinds, that are difficult to link/relate, perhaps ESD or supply spikes, or some handling could be the common denominator - the probability that it is just luck falls exponentially after every issue ) than 10 other shops combined. ---- '''p259 outputs''' - suspect if VR inputs do not work. * tachout works ? (eg. DC measurement, test mode; or other indication of p259 working well) * anything else on p259 ? Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.