_ __ | |/ / | ' / | < | . \ |_|\_\
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: I have a new NTK L1H1 WB02 Sensor, is it possible to use this instead of the Bosch LSU4.2 sensor? It seems the controller sold at wbo2.com has a jumper to change a resistor, but that only effects the HW RCal method. That's why we don't use NTK with round, but the software calibration method used in v3.x works without changing any resistor. Note that the small connector pinout is different (from the big, that is in the manual), and pump_pid_kp and pump_pid_ki values are appr. 1/3 of the Bosch sensor. In decimal, wbo2 pump PID values: * P=15 * I=23 * D=0 See WideBand Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.