_____ |_ _| | | | | _| |_ \___/
_____ (___ ) | | _ | | ( )_| | `\___/'
##### ## ## ## ## ##### ## ##
#### ## ## ## ## ## ####
### ##### ## ## ## ## ## ## ## ## ### ##
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: ''' EGT Issues''' The two EGT inputs worked fine last year with older firmware (1.0.18 or 1.0.19) but don't seem to work after a firmware upgrade to '''1.0.38'''. The symptom is that when a thermocouple is connected the temperature in MegaTune will display 0 with short spikes to what seems to multiples of 64 degrees at random intervals, about 1-2 times every second (this happens with nothing connected too). '''But...''' - If I put the thermocouple under a flame the temperature will stop fluttering and remain at 0. The input on the MCP3208 measures analog voltages that are appropriate for the ambient temperature. Using the same thermocouple (measuring ambient temperature I get): At the AD597 outputs * 0.29 V for EGT1 (top chip) * 0.19 V for EGT2 (bottom chip) At the MCP3208 : * 0.115 V on MCP3208_CH5 (EGT1) * 0.082 V on MCP3208_CH4 (EGT2) The measured voltages react in the expected way when the thermocouple is put under the flame (1.5 Volt ++), but this seems to be ignored. '''Q:''' Is the MCP3208 fried? (I think not..) '''Q:''' Or is there something I have forgotten to configure that has changed? '''Q:''' What happened to the egt_ variables ? (Here is the [http://www.vems.hu/files/MembersPage/MattiasSandgren/EricsVolvoTurbo/config.txt config file]) '''Q:''' Only one remains! Does it work for both channels? After v3.1, the mcp3208 channels (4,5 IIRC) that belong to EGT1 and EGT2 were swapped. Maybe you had old firmware compiled with MCP3208_EGT1 ? What does MegaTune show ? (or manually, with terminalprogram view-hex mode, ManbyeAAA at offset 24,25 and 26,27 of the A command's reply) Vital information! I have made the AREF modification by shorting with a piece of wire, and it works wonders for stability of analog inputs. I am having this exact same problem too - initially I thought it was a grouding issue because there were a few problems with the way the block was grounded. Everything works fine except for the spiking values of the EGT - exactly as you describe. //PhatBob Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.